KES - FB1 - A Tensile and Shear Tester

### Function of the Tester This tester can analyze and mechanize the hand movements of craftsmen and professionals during the evaluation of fabric style and hand - feel, such as "stretching" and "cutting". It converts the results into objective numerical data, and can obtain data on tensile/shear stiffness, tensile energy, elongation, and resilience of fabrics, papers, non - woven fabrics, films, etc. Tensile and shear characteristic data affect the "elasticity" and "tension" of the style and hand - feel, which in turn affect "shape stability" and "tendency to produce patterns". ### Features - **Improve data accuracy**: The sample is de - relaxed between the motor fixture and the clamping fixture to avoid measurement errors. - **Display resolution**: 0.01, which can digitally represent the differences in minor tensile and shear characteristics. ### Examples of Measured Samples All fibers, fabrics, medical fabrics, automotive seat cushions, interior fabrics, non - woven fabrics, film samples ### Specifications - **Dimensions/Weight**: Electronic amplifier device, W230×D450×H500(mm)/20kg - **Power Supply**: AC100V, maximum power consumption 40W - **Measurement Environment Temperature and Humidity**: 20~30°C/50~70%RH, no condensation. Maintain a certain temperature and humidity (standard temperature and humidity conditions: 20°C/65%RH). Install in a place less affected by wind and vibration. - **Measurement Actions**: Tensile measurement is in load control mode, and shear measurement is in deformation control mode. - **Tensile Load Detector**: Resistance wire strain gauge type - Load (full - scale): (Standard condition) 50kg, (High - sensitivity condition) 20kg - Standard condition: 10kgf(500gf/cm) - High - sensitivity condition: 1kgf(50gf/cm), with other variable settings available. - **Tensile Tension during Shearing** - (Standard condition): 200gf(10gf/cm) - (Variable setting condition): 100~1000gf (increments of 100gf) - Accuracy: Within ±0.5% of full - scale. - **Elongation Deformation Detector for Tensile Measurement**: Potentiometer - Elongation: Two - stage switching, maximum 25mm (50% tensile)/50mm (100% tensile). Accuracy: Within ±0.5% of full - scale. - Tensile deformation speed: 0.05~0.5mm/sec (increments of 0.05mm/sec) - Shear load detector: Differential transformer (ring - type dynamometer) - Load (full - scale): (Standard condition) 2kg - Accuracy: Within ±0.5% of full - scale. - Shear slip deformation detector: Potentiometer - Shear angle: Maximum 8° (50mm×tan8°≈7mm) - Standard condition: ±8° - Variable setting condition: ±0.8~8° (increments of 0.8°) - Accuracy: Within ±0.5% of full - scale. - Shear deformation speed: Fixed - Sample size: 20cm×20cm (standard) - Thickness: 2mm (maximum)
Leave Message Get Price