PLC Conveyor Belt Flammability and Flame Propagation Characteristics Tester

Scope
This tester is suitable for textile-reinforced conveyor belts and steel cord conveyor belts. It is also suitable for testing the flammability and flame propagation characteristics of horizontally oriented conveyor belt specimens.
Principle
Within a specified period, one end of a horizontally oriented conveyor belt specimen is exposed to a flame to evaluate, on a small scale, the conveyor belt's reaction to an ignition source. The duration of continued burning after removal of the burner flame is measured. After the flame has disappeared, an airflow is passed through the specimen to measure the duration of afterglow.
Applicable Standards
This tester is designed and manufactured in accordance with the requirements of AS 1334.10:1994, Determination of the Flammability and Flame Propagation Characteristics of Conveyor Belting, and ISO 340:2022, Conveyor Belts — Laboratory-Scale Flammability Characteristics — Requirements and Test Method.
Relevant Definitions
The following definitions are used in this test:
1. Flame duration: The time for which the specimen continues to burn after the burner beneath the specimen is removed following 60 seconds of exposure.
2. Afterglow: Slow combustion without a flame.
3. Flame period: The total flame duration for a single series of tests.
4. Afterglow period: The total afterglow duration for a single series of tests.
5. Acceptance test: A test conducted in accordance with AS 1334.10:1994 to demonstrate that a specimen complies with the specified technical requirements.
6. Type approval: Testing conducted in accordance with AS 1334.10:1994 for comprehensive product type qualification and product quality evaluation.
7. Vertical test: A test conducted in accordance with ISO 340:2022.
Instrument Specifications
Item | Specification |
Ignition time setting range | 0–999.9 s |
Burning time measurement range | 0–999.9 s |
Bunsen burner | Inner diameter: 10 ± 0.5 mm |
Bunsen burner rotation angle | Adjustable from 0° to 45° |
Thermocouple | Type K, sheathed |
Thermocouple display range | 0–1300°C |
Test flame temperature | 1000 ± 20°C |
Flame scale | 50–150/180 mm |
Internal dimensions of combustion chamber | 500 mm × 500 mm × 500 mm |
Combustion gas | Propane, purity >95% |
Dimensions (W × D × H) | 725 × 651 × 738 mm |
Weight (approx.) | ≈40 kg |
Power supply | AC 220 V ± 10%, 50–60 Hz |
Leave Message Get Price