Protection property

  • Protection property

I'm Online Chat Now


Floorings Thermal Radiation Panel Tester

Floorings Thermal Radiation Panel Tester

Skype / Email

  
The critical radiation flux is the main parameter to investigate the fire hazard of the flooring material. It characterizes the combustion spread capacity of the flooring material burned under the condition of external heat radiation. It is an important indicator in the grading system of flooring materials used as building products.
Floor material thermal radiation board test  meets the requirements of ISO9239-1,2 and GB / T 11785-2005. In the test chamber, the floor covering material is burned in a certain thermal radiation environment to measure the  critical thermal radiation value. It can also be used to measure the critical radiation value of attic floor cellulose insulation material.
 
Structure Features
1, All structural parts are made of stainless steel, beautiful, corrosion-resistant, durable.
2, Radiation heat source is the porous ceramic heat radiation plate 300mmX450mm, tilt 30°.
3, The United States imported calorimeter 50KW / ㎡.
4, The igniter diameter is 0.7mm, 19 / EA, at the position of 60 degrees from the bottom of each center.
5, the standard plate is made of  uncoated calcium silicate board at the thickness of  20 ± 1mm, density of 850 ± 100kg / m³, size 1050X250mm.
6, Small stainless steel ignition nozzle assists sample ignition.
7, Imported flow control valve, precise control of propane flow.
8, A blower to provide air source. The test gas is mixed through the Venturi mixed gas.

Optical System
 1, The optical system contains a light source of the 2900 ± 100 K color temperature incandescent lamp. Light source is received by the silicon photodiode, equipped with a optical path test shutter, for the use of  0% and 100% calibration.
2, Imported photovoltaic module measures the degree of light attenuation. The system automatically calculates the light transmission and generates light transmission curve, which is free to print.
 
Thermal Radiation System
1, Thermal radiation pyrometer accuracy of ± 0.5℃, about 1.4m away from the radiation panel.
2, Radiation pyrometer sensitivity keeps constant in the wavelength range of 1um ~ 9um.
3, High-performance K-armored thermocouple diameter of 3.2mm, with insulation and non-grounded hot junction, located at the position of  25mm under the roof the chamber and 100mm behind the flue wall .
4, the heat flow of the heat radiation panel surface shall be adjusted by a radiation pyrometer with a detectable diameter range of 250mm and a black body temperature range within 480℃~530℃.
4. Measure the heat flux from the heating panel to 110mm~910mm within the deviation at 110mm interval.
 5, in the error range, measured from the radiator to 110mm ~ 910mm within the heat flux, the interval is 110mm.
 
Control System
1.Standard control cabinet, embedded with an integrated 10.2" touch screen.
2. Sound alarm and alarmed accident display
3. USB / RS232 serial port on the control cabinet can connect desktop/notebook computer for operation control and free print of test reports.
4. Programmable logic controller (PLC) control system:

Specifications:
Power: AC220V±10%,50Hz;
Max. power:5KW;
Dimension:L×W×H(2.2×1.2×2.4)m;
Weight:350Kg.

Note:QINSUN is very in place for textile testing and quality control,we have our own textile testing lab. Our textile testing equipment and testing methods are in the leading position in the industry. We have passed the textile testing certification and iso textile testing standards issued by a number of testing,We can provide textile testing equipment pdf manual. Sufficient inventory, big discounts, limited time promotion, Order now!

Leave Message Get Price