Steel structure fire retardant paint sample test furnace

Technical parameters:
1. Working voltage: AC 220V± 10 50Hz; Power consumption: 3KW
2. Furnace pressure measurement range: 0-100Pa measurement accuracy amp; plusmn; 3Pa
3. Air flow: 0-50m3/min measurement accuracy amp; plusmn; 0.5 m3/min
4. Combustion gas source: propane, liquefied gas
5. Gas flow: 0-100L/min Measurement accuracy: 2.5
6. Gas tank capacity: 50kg× 2
Meet the standard:
GB14907-2002 fireproof coating for steel structure
GB/T9978-2008 Fire resistance test method for building elements
Technical specification for application of CECS24:90 fireproof coatings for steel structures
Note:QINSUN is very in place for textile testing and quality control,we have our own textile testing lab. Our textile testing equipment and testing methods are in the leading position in the industry. We have passed the textile testing certification and iso textile testing standards issued by a number of testing,We can provide textile testing equipment pdf manual. Sufficient inventory, big discounts, limited time promotion, Order now!
Leave Message Get Price